(Supported firmwares)
 
Line 4: Line 4:
 
* DR600
 
* DR600
  
== Supported firmwares ==
+
== Supported Models/CPS ==
  
* TR850 v3.42.xx ('''Site Link Authorisation''' is required)
+
* TR850 v3.42+ ('''Site Link Authorization''' is required)
 +
* DR600 v3.80 ('''Site Link Authorization''' is required)
  
 
== Configuration ==
 
== Configuration ==

Latest revision as of 00:18, 5 October 2024

Supported models

  • TR850
  • DR600

Supported Models/CPS

  • TR850 v3.42+ (Site Link Authorization is required)
  • DR600 v3.80 (Site Link Authorization is required)

Configuration

  • Communication protocol has to be set to Custom 2
  • UDP port 34420 of repeater has to be exposed (forwarded)
  • Default master port is 10405


Kirisun1.png

Several Kirisun repeaters behind a single IP

Allowed count can be configured at BrandMeister configuration. In this case each repeater's port 34420 has to be exposed (forwarded) as 34420 + N, where N is sequential number from 0 up to allowed count - 1 (34420, 34421, etc).