Starting BrandMeister release 20160421-112227 has support of WIRES-X connectivity.

WIRES-X Link allows:

Benefits[edit]

Conceptual view[edit]

BM-WIRES.png

Limitations[edit]

Additional features[edit]

Allocated ports[edit]

Configuration[edit]

WiresXLink :
{
  // DTMF ID of local node
  number = NODE ID;
  // Call of local node
  call = "<CALL-ND>";
  // DP-ID of local "radio"
  serial = "xxxxx";
  // Connection profiles
  connections =
  [
    "RoomXXXXX",
    "RoomXXXXX"
  ];  
};

RoomXXXXX :
{
  // Room ID: ITALY
  // Group ID
  number = TG number;
  // Remote node address
  address = "<IP ADRESS or Domain Name>";
  // Connection mode:
  // 0 - Regular
  // 1 - Persistent
  // 2 - Regular, auto-reconnect on inactivity
  // 3 - Persistent, auto-reconnect on inactivity
  mode = 0;
};

Issues with connectivity[edit]

No sound from WIRES-X at all, BM Status web page shows “0 members”[edit]

Check your firewall rules, port UDP 46112 should be allowed.

DMR radio (and Last Heard) shows talking group number instead ID of operator[edit]

Autodiscovery[edit]

Autodiscovery mode is an alternative mode to connect to WIRES-X rooms. In that mode there is no need to configure profiles in main configuration file. Instead of it the system connects to Yaesu's WIRES-X directory servers and track the changes. To use this mode you have to have an WIRES-X node ID from Yaesu and HRI-200 serial number. There numbers should never be used by another connected WIRES-X node.

Registry.json[edit]

  "plugs" :
  {
    "210-FusionDirector" :
    {
      "WiresNodeID" : <ID of registered WIRES-X node used to connect Yaesu directory servers (ID should not be used by another WIRES-X client)>,
      "HRISerial" : "<HRI-200 serial number, it should not be used by another WIRES-X client>"
    }
  }

WiresSubscriptions[edit]

  Space WiresSubscriptions:
    1 - BrandMeister Instance ID
    2 - BrandMeister Application ID
    3 - DMR Group ID
    4 - WIRES-X Room ID

  box.space.WiresSubscriptions:replace({ 2621, 262100, 262100, 24007 })