m (→Timers) |
m (→Timers) |
||
Line 29: | Line 29: | ||
== Timers == | == Timers == | ||
− | Master Servers controls two main timers for system usage. <b>Hold-Off</b> (Hand-Off) Timer and <b>On-Demand</b> (Dynamic Talk Group) | + | Master Servers controls two main timers for system usage. <b>Hold-Off</b> (Hand-Off) Timer and <b>On-Demand</b> (Dynamic Talk Group) Timer. |
− | '''Hold-Off''' (Hand-Off) is set for <b>3 minutes</b> on IT Master Server. This timer function will Hold-Off all other Talk Groups on a Time Slot when a user activates a Dynamic Talk Group and will Hold-Off (Keep Clear) the other Dynamic and Static Talk Groups on a Time Slot for a period of 3 minutes. | + | '''Hold-Off''' (Hand-Off) is set for <b>3 minutes</b> on IT Master Server. This timer function will Hold-Off all other Talk Groups on a Time Slot when a user activates a Dynamic Talk Group and will Hold-Off (Keep Clear) the other Dynamic and Static Talk Groups on a Time Slot for a period of 3 minutes. It's a sort of priority/protection for the last Key-Up Dynamic Talk Group on the repeater Time Slot. |
− | '''On Demand Timer''' (Dynamic Talk Group) is set for <b>10 minutes</b> on IT Master Server. This timer function provides for when a user | + | '''On Demand Timer''' (Dynamic Talk Group) is set for <b>10 minutes</b> on IT Master Server. This timer function provides for when a user Keys-Up a Dynamic Talk Group and will stay active for a period of 10 minutes. Once the timer exceeds this time, with no PTT activity on the repeater, the Dynamic Talk Group will Drop Off. |
− | '''Auto Static''' is for simplex based Hotspots, where a Key-Up Talk Group is set Static automatically, to allow use of the activated Talk Group indefinitely, even after the On-Demand Timer resets. To remove the Auto Static Talk Group either Key-Up another Talk Group or use <b>TG-4000</b> to clear the Auto Static Talk Group. You don't have to use TG-4000 when moving to another TG; this only is used if you want to disconnect for all Talk Groups currently set Auto Static on your Hotspot. | + | '''Auto Static''' is for simplex based Hotspots, where a Key-Up Talk Group is set Dynamic and also Static automatically, to allow use of the last activated Talk Group indefinitely, even after the On-Demand Timer resets. To remove the Auto Static Talk Group either Key-Up another Talk Group or use <b>TG-4000</b> to clear the Auto Static Talk Group. You don't have to use TG-4000 when moving to another TG; this only is used if you want to disconnect for all Talk Groups currently set Auto Static on your Hotspot. |
== Hoseline == | == Hoseline == |
Italy | |
---|---|
MCC Prefix | 222, 223, 224 |
Coordinators | IZ2XBZ, IZ2FTR, |
Website | https://dmrbrescia.it |
DMR ID | Managed by | Location | Remarks
|
---|---|---|---|
2222 | IZ2XBZ, IZ2FTR, IW2KPM, IZ7JWR, IK5XMK, | Brescia, IT | Hosted by DMR Brescia Team
Italian Master Server IP: bm2222.dmrbrescia.it (80.211.95.98) Contact email address is bm2222@dmrbrescia.it |
Users connecting hotspots to BrandMeister IT Servers will be required have a Selfcare account and to set their hotspot security password..
Visit https://www.dmrbrescia.it/assegnazione-password-sulle-connessioni/ for detailed information on how to connect hotspots to BrandMeister.
Users connecting repeaters to BrandMeister IT Servers will be required have a Selfcare account and to set their repeater security password..
Visit https://www.dmrbrescia.it/assegnazione-password-sulle-connessioni/ for detailed information on how to connect repeaters to BrandMeister.
Master Servers controls two main timers for system usage. Hold-Off (Hand-Off) Timer and On-Demand (Dynamic Talk Group) Timer.
Hold-Off (Hand-Off) is set for 3 minutes on IT Master Server. This timer function will Hold-Off all other Talk Groups on a Time Slot when a user activates a Dynamic Talk Group and will Hold-Off (Keep Clear) the other Dynamic and Static Talk Groups on a Time Slot for a period of 3 minutes. It's a sort of priority/protection for the last Key-Up Dynamic Talk Group on the repeater Time Slot.
On Demand Timer (Dynamic Talk Group) is set for 10 minutes on IT Master Server. This timer function provides for when a user Keys-Up a Dynamic Talk Group and will stay active for a period of 10 minutes. Once the timer exceeds this time, with no PTT activity on the repeater, the Dynamic Talk Group will Drop Off.
Auto Static is for simplex based Hotspots, where a Key-Up Talk Group is set Dynamic and also Static automatically, to allow use of the last activated Talk Group indefinitely, even after the On-Demand Timer resets. To remove the Auto Static Talk Group either Key-Up another Talk Group or use TG-4000 to clear the Auto Static Talk Group. You don't have to use TG-4000 when moving to another TG; this only is used if you want to disconnect for all Talk Groups currently set Auto Static on your Hotspot.
This service allows for users to monitor (listen) to talk groups from a web browser. Visit https://hose.brandmeister.network.
Most used Italian TalkGroups & Cluster External Talk Groups (Cluster Internal Talk Group 88)
Important general operational notes:
Before starting QSOs on any TalkGroup (national, international, regional, etc.), always first check the configuration of the static TalkGroups on the repeater you desire to use.
If your TG is configured as static on one of the two Time-Slots, please use the relevant Time-Slot.
If your TG is not configured as static on either Time-Slot, ask yourself where your QSO will have the least impact on existing traffic and based on this consideration choose the best slot.
If you see that one of the two Time-Slots is completely free of static TalkGroups, choose it, because it means that the Sysop evidently likes to host you on that slot, dedicated anytime to free traffic on any TalkGroup.
(Last change: September 30th, 2023 by IV3BVK)
Time Slot | Talk Group | Notice |
---|---|---|
1-2 | 1 | Local Only |
1-2 | 9 | Local Only |
2 | 88 | Geographical Clusters Internal TalkGroup (Time Slot-2 Preferred) |
1 | 222 | Italy Nation Wide (It should be mainly used only for short QSO's - Consider moving to a smaller footprint TalkGroup or TAC) |
1 | 916 | Italian (Language) |
■■■■■■ Italian Regional TalkGroups | ||
1-2 | 22201 | Regional LAZIO |
1-2 | 22202 | Regional SARDEGNA |
1-2 | 22203 | Regional UMBRIA |
1-2 | 22211 | Regional LIGURIA |
1-2 | 22212 | Regional PIEMONTE |
1-2 | 22213 | Regional VALLE d'AOSTA |
1-2 | 22221 | Regional LOMBARDIA |
1-2 | 22231 | Regional FRIULI VENEZIA GIULIA |
1-2 | 22232 | Regional TRENTINO ALTO ADIGE |
1-2 | 22233 | Regional VENETO |
1-2 | 22241 | Regional EMILIA ROMAGNA |
1-2 | 22251 | Regional TOSCANA |
1-2 | 22261 | Regional ABRUZZO |
1-2 | 22262 | Regional MARCHE |
1-2 | 22271 | Regional PUGLIA |
1-2 | 22281 | Regional BASILICATA |
1-2 | 22282 | Regional CALABRIA |
1-2 | 22283 | Regional CAMPANIA |
1-2 | 22284 | Regional MOLISE |
1-2 | 22291 | Regional SICILIA |
■■■■■■ Italian TalkGroups for associations (Preferable on Hot Spots or Time Slot-1 for Repeaters) | ||
1 | 22288 | A.R.I. - Associazione Radioamatori Italiani |
1 | 22287 | C.I.S.A.R. - Centro Italiano Sperimentazione ed Attività Radiantistiche |
1 | 22289 | E.R.A. European Radioamateurs Association |
1 | 22290 | A.R.F.I. Associazione Radioamatori Finanzieri Italiani |
■■■■■■ Italian Clusters (Internal TG-88 preferable on Time Slot-2 - External TG preferable on Hot Spots or Time Slot-1) | ||
1 | 22877 | Cluster Rezia-CH |
1 | 222030 | Cluster Brescia |
1 | 222031 | Cluster Dolomiti |
1 | 222037 | Cluster Ragusa |
1 | 222039 | Cluster Salento |
1 | 222049 | Cluster Insubria |
1 | 222051 | Cluster Reno |
1 | 222052 | Cluster Golfo di Gaeta |
1 | 222055 | Cluster D2ALP - Appennino Ligure Piemontese |
1 | 222056 | Cluster Agrigento |
1 | 222059 | Cluster Verona |
1 | 222060 | Cluster Catania |
1 | 222061 | Cluster Palermo |
1 | 222063 | Cluster Terni |
1 | 222064 | Cluster Savona |
1 | 222066 | Cluster Castellammare di Stabia |
1 | 222067 | Cluster Rovigo |
1 | 222068 | Cluster Perugia |
1 | 222070 | Cluster Avellino |
1 | 222071 | Cluster Villa San Giovanni |
1 | 222072 | Cluster Val di Bisenzio |
1 | 222073 | Cluster Agro Nocerino Sarnese |
1 | 222074 | Cluster Valli Canavesane |
1 | 222075 | Cluster Val di Susa |
1 | 222090 | Cluster Stretto di Messina |
1 | 222111 | Cluster Gruppo DMR R.N.R.E. |
1 | 222383 | Cluster Nord-Est C.I.S.A.R. |
1 | 222410 | Cluster Montefeltro |
1 | 222666 | Cluster ANCONA |
1 | 222773 | Cluster ROMA/LATINA |
■■■■■■ TAC - Italian Tactical TalkGroups (Slot-1 ONLY) | ||
1 | 222001 | IT TAC-01 |
1 | 222002 | IT TAC-02 |
1 | 222003 | IT TAC-03 |
1 | 222004 | IT TAC-04 |
1 | 222005 | IT TAC-05 |
1 | 222006 | IT TAC-06 |
1 | 222007 | IT TAC-07 |
1 | 222008 | IT TAC-08 |
1 | 222009 | IT TAC-09 |
1 | 222010 | IT TAC-10 |
■■■■■■ Italian National Links | ||
1 | 22292 | Italia-MP |
1 | 22298 | Italy-Nord |
■■■■■■ Experimantal TalkGroups 224xx | ||
1 | 22400 | Wires-X Room ITALIA CISAR Multiprotocol Link |
1 | 22402 | C.I.S.O.M. |
1 | 22404 | A.I.R.S. |
1 | 22406 | AllStarLink |
1 | 22407 | Onda Telematica |
1 | 22411 | STEVU Room |
1 | 22412 | IU1DXU - ARI Chivasso |
1 | 22420 | IQ2AQ-L SVX (Link ID YSF: 23053) |
1 | 22421 | Ass. Polo Positivo |
1 | 22422 | Italy Sperimantale IR1DT |
1 | 22431 | Gruppo Radio Marmolada |
1 | 22480 | Digiland Italy Group multiprotocol Link |
1 | 22481 | Gruppo AMRS - Ass. Marconi Radioamatori Sperimentatori |
1 | 22482 | Gruppo Radio Gioiesi |
1 | 22486 | Gruppo Radioamatori G.P.G. (Time Slot-1 Preferable) |
1 | 22487 | Multiprotocollo Italy Centro |
1 | 22491 | C4FM Test MMDVM( IW9GRL) |
1 | 22497 | C.I.S.A.R. Agrigento |
1 | 22498 | PIRS Sicilia |
■■■■■■ Emergency TalkGroup ■■■■■■ | ||
1-2 | 222112 | Italian Global Emergency-112 - INTENDED TO BE USED ONLY FOR REAL EMERGENCY - NO QSO - NO TESTS !!! |
■■■■■■ Special TalkGroups | ||
1 | 222907 | Italian JOTA Radio Scout (Time Slot-1 Preferable) |
Support for reflectors has been removed worldwide from BrandMeister on Dec 31st, 2020.
Please note that 222999 is a global destination, no need to change it if you are travelling to different countries.
- Hytera repeaters
- Motorola repeaters
- Connected Repeaters List
- Connected C4FM Reflectors List
- Hotspot and repeater configuration to connect the desired regional room on the YSF22220 reflector
Italy | |
---|---|
MCC Prefix | 222, 223, 224 |
Coordinators | IZ2XBZ, IZ2FTR, |
Website | https://dmrbrescia.it |
DMR ID | Managed by | Location | Remarks
|
---|---|---|---|
2222 | IZ2XBZ, IZ2FTR, IW2KPM, IZ7JWR, IK5XMK, | Brescia, IT | Hosted by DMR Brescia Team
Italian Master Server IP: bm2222.dmrbrescia.it (80.211.95.98) Contact email address is bm2222@dmrbrescia.it |
Users connecting hotspots to BrandMeister IT Servers will be required have a Selfcare account and to set their hotspot security password..
Visit https://www.dmrbrescia.it/assegnazione-password-sulle-connessioni/ for detailed information on how to connect hotspots to BrandMeister.
Users connecting repeaters to BrandMeister IT Servers will be required have a Selfcare account and to set their repeater security password..
Visit https://www.dmrbrescia.it/assegnazione-password-sulle-connessioni/ for detailed information on how to connect repeaters to BrandMeister.
Master Servers controls two main timers for system usage. Hold-Off (Hand-Off) Timer and On-Demand (Dynamic Talk Group) Timer.
Hold-Off (Hand-Off) is set for 3 minutes on IT Master Server. This timer function will Hold-Off all other Talk Groups on a Time Slot when a user activates a Dynamic Talk Group and will Hold-Off (Keep Clear) the other Dynamic and Static Talk Groups on a Time Slot for a period of 3 minutes. It's a sort of priority/protection for the last Key-Up Dynamic Talk Group on the repeater Time Slot.
On Demand Timer (Dynamic Talk Group) is set for 10 minutes on IT Master Server. This timer function provides for when a user Keys-Up a Dynamic Talk Group and will stay active for a period of 10 minutes. Once the timer exceeds this time, with no PTT activity on the repeater, the Dynamic Talk Group will Drop Off.
Auto Static is for simplex based Hotspots, where a Key-Up Talk Group is set Dynamic and also Static automatically, to allow use of the last activated Talk Group indefinitely, even after the On-Demand Timer resets. To remove the Auto Static Talk Group either Key-Up another Talk Group or use TG-4000 to clear the Auto Static Talk Group. You don't have to use TG-4000 when moving to another TG; this only is used if you want to disconnect for all Talk Groups currently set Auto Static on your Hotspot.
This service allows for users to monitor (listen) to talk groups from a web browser. Visit https://hose.brandmeister.network.
Most used Italian TalkGroups & Cluster External Talk Groups (Cluster Internal Talk Group 88)
Important general operational notes:
Before starting QSOs on any TalkGroup (national, international, regional, etc.), always first check the configuration of the static TalkGroups on the repeater you desire to use.
If your TG is configured as static on one of the two Time-Slots, please use the relevant Time-Slot.
If your TG is not configured as static on either Time-Slot, ask yourself where your QSO will have the least impact on existing traffic and based on this consideration choose the best slot.
If you see that one of the two Time-Slots is completely free of static TalkGroups, choose it, because it means that the Sysop evidently likes to host you on that slot, dedicated anytime to free traffic on any TalkGroup.
(Last change: September 30th, 2023 by IV3BVK)
Time Slot | Talk Group | Notice |
---|---|---|
1-2 | 1 | Local Only |
1-2 | 9 | Local Only |
2 | 88 | Geographical Clusters Internal TalkGroup (Time Slot-2 Preferred) |
1 | 222 | Italy Nation Wide (It should be mainly used only for short QSO's - Consider moving to a smaller footprint TalkGroup or TAC) |
1 | 916 | Italian (Language) |
■■■■■■ Italian Regional TalkGroups | ||
1-2 | 22201 | Regional LAZIO |
1-2 | 22202 | Regional SARDEGNA |
1-2 | 22203 | Regional UMBRIA |
1-2 | 22211 | Regional LIGURIA |
1-2 | 22212 | Regional PIEMONTE |
1-2 | 22213 | Regional VALLE d'AOSTA |
1-2 | 22221 | Regional LOMBARDIA |
1-2 | 22231 | Regional FRIULI VENEZIA GIULIA |
1-2 | 22232 | Regional TRENTINO ALTO ADIGE |
1-2 | 22233 | Regional VENETO |
1-2 | 22241 | Regional EMILIA ROMAGNA |
1-2 | 22251 | Regional TOSCANA |
1-2 | 22261 | Regional ABRUZZO |
1-2 | 22262 | Regional MARCHE |
1-2 | 22271 | Regional PUGLIA |
1-2 | 22281 | Regional BASILICATA |
1-2 | 22282 | Regional CALABRIA |
1-2 | 22283 | Regional CAMPANIA |
1-2 | 22284 | Regional MOLISE |
1-2 | 22291 | Regional SICILIA |
■■■■■■ Italian TalkGroups for associations (Preferable on Hot Spots or Time Slot-1 for Repeaters) | ||
1 | 22288 | A.R.I. - Associazione Radioamatori Italiani |
1 | 22287 | C.I.S.A.R. - Centro Italiano Sperimentazione ed Attività Radiantistiche |
1 | 22289 | E.R.A. European Radioamateurs Association |
1 | 22290 | A.R.F.I. Associazione Radioamatori Finanzieri Italiani |
■■■■■■ Italian Clusters (Internal TG-88 preferable on Time Slot-2 - External TG preferable on Hot Spots or Time Slot-1) | ||
1 | 22877 | Cluster Rezia-CH |
1 | 222030 | Cluster Brescia |
1 | 222031 | Cluster Dolomiti |
1 | 222037 | Cluster Ragusa |
1 | 222039 | Cluster Salento |
1 | 222049 | Cluster Insubria |
1 | 222051 | Cluster Reno |
1 | 222052 | Cluster Golfo di Gaeta |
1 | 222055 | Cluster D2ALP - Appennino Ligure Piemontese |
1 | 222056 | Cluster Agrigento |
1 | 222059 | Cluster Verona |
1 | 222060 | Cluster Catania |
1 | 222061 | Cluster Palermo |
1 | 222063 | Cluster Terni |
1 | 222064 | Cluster Savona |
1 | 222066 | Cluster Castellammare di Stabia |
1 | 222067 | Cluster Rovigo |
1 | 222068 | Cluster Perugia |
1 | 222070 | Cluster Avellino |
1 | 222071 | Cluster Villa San Giovanni |
1 | 222072 | Cluster Val di Bisenzio |
1 | 222073 | Cluster Agro Nocerino Sarnese |
1 | 222074 | Cluster Valli Canavesane |
1 | 222075 | Cluster Val di Susa |
1 | 222090 | Cluster Stretto di Messina |
1 | 222111 | Cluster Gruppo DMR R.N.R.E. |
1 | 222383 | Cluster Nord-Est C.I.S.A.R. |
1 | 222410 | Cluster Montefeltro |
1 | 222666 | Cluster ANCONA |
1 | 222773 | Cluster ROMA/LATINA |
■■■■■■ TAC - Italian Tactical TalkGroups (Slot-1 ONLY) | ||
1 | 222001 | IT TAC-01 |
1 | 222002 | IT TAC-02 |
1 | 222003 | IT TAC-03 |
1 | 222004 | IT TAC-04 |
1 | 222005 | IT TAC-05 |
1 | 222006 | IT TAC-06 |
1 | 222007 | IT TAC-07 |
1 | 222008 | IT TAC-08 |
1 | 222009 | IT TAC-09 |
1 | 222010 | IT TAC-10 |
■■■■■■ Italian National Links | ||
1 | 22292 | Italia-MP |
1 | 22298 | Italy-Nord |
■■■■■■ Experimantal TalkGroups 224xx | ||
1 | 22400 | Wires-X Room ITALIA CISAR Multiprotocol Link |
1 | 22402 | C.I.S.O.M. |
1 | 22404 | A.I.R.S. |
1 | 22406 | AllStarLink |
1 | 22407 | Onda Telematica |
1 | 22411 | STEVU Room |
1 | 22412 | IU1DXU - ARI Chivasso |
1 | 22420 | IQ2AQ-L SVX (Link ID YSF: 23053) |
1 | 22421 | Ass. Polo Positivo |
1 | 22422 | Italy Sperimantale IR1DT |
1 | 22431 | Gruppo Radio Marmolada |
1 | 22480 | Digiland Italy Group multiprotocol Link |
1 | 22481 | Gruppo AMRS - Ass. Marconi Radioamatori Sperimentatori |
1 | 22482 | Gruppo Radio Gioiesi |
1 | 22486 | Gruppo Radioamatori G.P.G. (Time Slot-1 Preferable) |
1 | 22487 | Multiprotocollo Italy Centro |
1 | 22491 | C4FM Test MMDVM( IW9GRL) |
1 | 22497 | C.I.S.A.R. Agrigento |
1 | 22498 | PIRS Sicilia |
■■■■■■ Emergency TalkGroup ■■■■■■ | ||
1-2 | 222112 | Italian Global Emergency-112 - INTENDED TO BE USED ONLY FOR REAL EMERGENCY - NO QSO - NO TESTS !!! |
■■■■■■ Special TalkGroups | ||
1 | 222907 | Italian JOTA Radio Scout (Time Slot-1 Preferable) |
Support for reflectors has been removed worldwide from BrandMeister on Dec 31st, 2020.
Please note that 222999 is a global destination, no need to change it if you are travelling to different countries.
- Hytera repeaters
- Motorola repeaters
- Connected Repeaters List
- Connected C4FM Reflectors List
- Hotspot and repeater configuration to connect the desired regional room on the YSF22220 reflector